Diesel Generator Day Tank 101: All the Basics You Need to Know in 2022

Petroleum products company, Remote fill station, Fill Box,

Diesel Generator Day Tank 101: All the Basics You Need to Know in 2022

Diesel generator day tanks are an important part of any business that relies on a diesel generator for backup power. In this article, we will discuss the basics of diesel generator day tanks so that you can make sure your business is prepared for anything in 2022.

What You Need to Know in 2022

With so many options on the market, it can be tough to choose the right diesel generator day tank for your needs. In this blog post, we’ll go over all the basics you need to know to make an informed decision in 2022.

Diesel generators are a vital part of many businesses’ operations, providing backup power in case of an outage or emergency. Day tanks are used to store the fuel for these generators, and they come in a variety of sizes and styles to meet different needs.

What is a Diesel Generator Day Tank?

A diesel generator day tank is simply a holding tank for your diesel generator’s fuel. This fuel is used to power the generator and keep it running smoothly. The day tank ensures that there is a consistent supply of fuel available to the generator, so it can keep running smoothly and efficiently.

Choosing a Day Tank

When choosing a day tank, there are several factors to keep in mind, such as:

  • Capacity: How much fuel will you need to store?
  • Dimensions: What are the physical dimensions of the space you have to work with?
  • Connection Type: What type of connection will you need to connect your generator to the day tank?
  • Pump Type: What type of pump do you need?

Capacity: How much fuel will you need to store?

This is one of the most important questions to answer when considering a Diesel Generator Day Tank. You will want to determine how much fuel you will need to store based on your power needs and usage. A good rule of thumb is to estimate that you will need 100 gallons of fuel for every 1000 hours of generator operation. This means that if you plan on using your generator for 50 hours per week, you will need a minimum of 500 gallons of fuel storage.

Dimensions: What are the physical dimensions of the space you have to work with?

The dimensions of the tank will dictate how much fuel it can hold, and how much weight it can support.

There are two main types of Diesel Generator Day Tanks: above-ground tanks and below-ground tanks. Above-ground tanks are typically rectangular, while below-ground tanks can be either rectangular or cylindrical.

  • Above-ground tanks also have the advantage of being easier to inspect and maintain. However, they are more susceptible to damage from flooding or other natural disasters. 
  • Below-ground tanks are generally more expensive to install, but they offer better protection from the elements. These tanks should be installed by a professional contractor with experience in excavating and installing underground fuel storage tanks.

If you have limited space, you may want to consider an above-ground tank. These tanks are typically easier to install and require less excavation than below-ground tanks.

Connection Type: What type of connection will you need to connect your generator to the day tank?

There are two types of connections that can be used to connect a generator to a day tank – threaded and quick-connect. The type of connection you will need will depend on the model of generator you have.

Threaded connections are the most common type of connection and are typically found on older model generators. Quick-connect connections are newer and more convenient, but they may not be compatible with all models of generators.

Pump Type: What type of pump do you need?

There are two main types of pumps: positive displacement and centrifugal. Positive displacement pumps work by trapping a certain amount of fluid and then moving it in a piston-like fashion. Centrifugal pumps, on the other hand, utilize an impeller to draw fluid into the center of the pump where it is then expelled outward. Diesel generators usually require positive displacement pumps due to their higher pressure output needs.

When determining which type of pump you need, also consider the flow rate that your diesel generator will require. This is typically measured in gallons per minute (GPM). The size of your day tank will also dictate how often you will need to refill it, so be sure to take that into account as well.

What is the purpose of a fuel pump in a generator?

It is simply a matter of flipping two switches to cause the fuel pump to engage. It draws petrol from the day tank or fuel supply header and delivers it at the proper pressure to the fuel injectors. During light loads, this pump moves more petrol than the generator will use. Various components are cooled by circulating unused fuel through them as a method of temperature control.



Contact the Premier Source for Remote Fill Systems

Remote Fill Systems is the premier source for remote fill tanks and systems for generator fueling. We are committed to providing knowledgeable and experienced support to our customers from design and application through startup and commissioning. Our team has many years of experience with fuel oil as well as long experience in industrial process control and mechanical HVAC and piping systems. We have developed innovative and cost-effective products in response to customer needs, such as:

Pumped Remote Fill: The pumped remote fill is unique in its small 2 x 2 x 2 size. Small but powerful, the pumped remote fill is for applications that exceed 4 stories, which is the practical pressure limit for a diesel fuel delivery truck. The pumped remote fill unit is pre-assembled and factory tested. It is paired with a matching control panel with status indicating lights and a motor starter. The unit may be ordered for flush or surface mount.